PIR detector; cylindrical lens; coverage angle: 90°; coverage distance: 1.5 -12 m; 54 detection zones
adaptive pulse count: 1 pulse / Auto; RF and EM Immunity; ESD protection; PET immunity - up to
12kg; temperature compensation; operating temperature from -20° up to+50°C; bracket - optional. |
|
| TITAN DL |
DIGITAL PIR detector; cylindrical lens; coverage angle: 90°; coverage distance from 1.5m up to 15m; 54
detection zones; adaptive pulse count: 1 pulse / Auto (PET); RF and EM Immunity; ESD protection; WLI (White
Light Immunity) - 4000lux; PET immunity for higher protection security - 12/20kg (selectable); digital bidirectional
temperature compensation; operating temperature range from -20°C up to +50°C.
Option - bracket for wall or ceiling mounting |
|
|
DIGITAL PIR detector with QUAD element; cylindrical lens; coverage angle: 90°; coverage distance from
1.5m up to 15m; 54 detection zones; adaptive pulse count: 1/ 2 pulse (PET); RF and EM Immunity; ESD protection;
excellent WLI (White Light Immunity) - 6500lux; PET immunity for higher protection security - 25/40
kg (selectable); digital bidirectional temperature compensation; operating temperature range from -20°C up to
+50°C. Option - bracket for wall or ceiling mounting |
|
|
Dual technology (PIR+MW) detector with wide angle cylindrical lens; DIGITAL Analysis; coverage
distance for the PIR element: 1.5 - 13 m, coverage distance for the MW element 5 - 15 m (adgustable); sensitivity addjustment for MW and PIR par ts; RF and EM Immunity; ESD protection; LED
indication for the operating status:PIR, MW, ALARM; operating temperature from -20° up to +50°C;
bracket-optional. |
|
|
Dual technology (PIR+MW) detector with wide angle cylindrical lens; DIGITAL Analysis; AntiMasking
and AntiSpray functions; coverage distance for the PIR element: 1.5 - 13 m, coverage distance for
the MW element 5 - 15 m (adgustable); sensitivity addjustment for MW, PIR and AM elements; RF
and EM Immunity; ESD protection; LED indication for the operating status: PIR, MW, ALARM; operat-
ing temperature from -20° up to +50°C; covers GRADE 3 for EN 50131; bracket-optional |
|
|
Dual technology (PIR+glass break) detector with wide angle cylindrical lens; Coverage area for GB element: up to 12m; Coverage area for PIR element: from 1.5 up to 12 m; sensitivity addjustment for GB
and PIR elements; RF and EM Immunity; ESD protection; operating temperature from -20° up to +50°C;
bracket-optional. |
|